1 L.Fàbrega, on behalf of the XMS-ESP consortium XMS sensor array development in Spain XMS sensor array development in Spain
2 XMS-ESP team for sensor development Leadership/management: IFCA (Santander): X. Barcons Sensor array development (with SRON): IMM (Madrid): J.L. Costa-Krämer, P.Val ICMA (Zaragoza), A. Camón, C.Pobes ICMAB (Barcelona): L. Fàbrega ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
3 Full work plan No estoy segura de ponerla esta. Cómo lo veis? Me preocupa también qué decir sobre la financiación y perspectivas de futuro… ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
4 Lab facilities Existing CSIC laboratory network for: Deposition and lithography Structural characterization Cryogenic tests Expertise in fabricating highest quality Mo/Au TESs Collaboration with SRON to develop absorber Pixel testing being set Ésta está copiada (no 100%) de lo que presentamos en Ginebra el año pasado. Se os ocurre algún título/planteamiento mejor? ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
5 Mo/Au bilayers d Au =115 and 215nm Typical values: ≈ 600; R N ≈ 25m (can be tuned without affecting T c, ) Ésta y la siguiente las he copiado del ppt de Ginebra. Luego he añadido las I-V. Entre las 3, reproducen el póster de la ASC… ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
6 Mo/Au: Stability & Homogeneity Stable when heated up to 150ºC (annealing) Homogeneous within at least 2x2cm 2 4’ wafer ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
7 I-V curves G=1.08nW/K ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
8 Work plan for 2013 Currently working on: Fine-tuning Mo/Au deposition conditions First tests of Bi electrochemical deposition Tests of homogeneity over large areas (4’’) Setup for full pixel testing (will be ready by end of june) Fabrication of a single pixel Cooperation with SRON with design and lithography ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
9 Algo sobre el setup de caracterización: -Foto(s) -Detalles -… ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
10 Electrodeposited Bi layers V=-0.02V t= 2.2 m V=-0.07V t= 10 m V=-0.04V t= 2 m Provisional, según si hay más resultados Al menos habría que añadir y tamaño grano de éstas ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013
11 Pixel design Significant differences between SRON (Ti/Au) and GSFC (Mo/Au): Need for banks or fingers? Absorber material and shape? Are these conditioned by TES’s material? Start with SRON design and further test/optimize
12 Conclusions Pixel design and fabrication under way (with the help of SRON) Pixel characterization setup to be ready mid- 2013 Homogeneity tests previous to array fabrication under way Funding garanted for 2013+ XMS development plan necessary to obtain funding for next phases Sensor development by XMS-ESP ATHENA sensor development in Spain L.Fàbrega Utrecht, March 6 2013